FAQ

Many common software questions are answered in the categories below. If you can’t find a response for yours, try checking our User Forum, or, contact HelpDesk for direct assistance


Metrix » QC Errors/Warnings
Q: WARNING: \"Meter inadequately tuned (CVRMSE Eng > 25.0; CVRMSE Dmd >35.0)\"

A:  ASHRAE Guideline 14 says that the CVRMSE should be <25% for energy, and <35% for demand. The CVRMSE is almost the Root Mean Square of the deviations. It is roughly a measure of the average distance of the points from the fit line. Many see the CVRMSE as being more important than the R2 value.

Just as with the \"R2 < .75\" warning, there is no way to remedy this warning without tuning the meter properly.

I can’t find the answer to your question ? Try checking our User Forums.

Otherwise feel free to contact our Tech Support staff at (805) 329-6565, or via email at helpdesk@abraxasenergy.com.




MetrixMarketManagerReportMakerOption C